GridFree MicroInverter LED Status Error
When problem is detected, the STATUS LED will display error in RED color
Internal Errors 1x Red - Primary Over Current, main circuit current is too big 2x Red - Internal Over Current 3x Red - Internal Over Voltage 4x Red - Internal Under Voltage 8x Red - Grid Synchronization is not OK 9x Red - Safety problem detected
Grid Errors or Grid is not stable 5x Red - The grid is not OK, may be voltage, frequency, or other thing of the grid are not OK. MicroInverter will try later to resume function. 6 x Red - Grid Over Frequency 7 x Red - Grid Under Frequency 10 x Red - Grid Over Voltage 11 x Red - Grid Under Voltage
Input Errors 13 x Red - DC input voltage error. The DC input voltage is out of working range of the MicroInverter.
Temperature Errors 12 x Red - Heat Sink Over Heat – the inner temperature is too high 14 x Red - Internal temperature error
|