What BMS is suitable for LFP/LTO/Li-Ion cells

Each Lithium technology of cell has different voltage levels and the BMS must support the Low (discharge) and High (charge) voltage level of the cell.

Following table shows the lowest and higest supported voltage values. YES means the BMS supports the technology.

 

 Graph


*The minimum amount of LTO cells at BMSs05 is 7pcs in serial connection. The reason is total system minimum voltage 11V.
 

Please note the SBM/CBM modules have fixed voltage levels. So read discription of SBM module carefuly to meet the cell voltage requirements.