Sinopoly 300AH cell discharge diagram

 

Sinopoly 300AH cell discharge diagram

The diagram shows the discharge of the Sinopoly 300AH cell at 0.3C rate, at room temperature. This is a 100% DOD cycle, with discharge up to 2.5V.  

This diagram shows that reaching the 3.0V level at the 0.3C rating corresponds to 90% DOD. 